3. Replace the Intake Grille.
(1) Hook the ropes.
(2) Set the left and right mounting shafts into the bearings at the bottom
of the panel.
(3) Press the place where the mark on the diagram indicates and close
the intake grille.
2
Intake
1
Grille
3
Rope
Cleaning the Air Filter
1. Open the Intake Grille, and remove the air fi lter.
Push down the air fi lter's handle, disconnect
the 2 upper tabs, and pull out.
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the Air Filter and close the Intake Grille.
(1) Align the sides of the air fi lter with the panel, and push in fully, making
sure the 2 upper tabs are returned properly to their holes in the panel.
AIR FILTER
PANEL
(2) Close the Intake Grille.
● Dust can be cleaned from the air fi lter either with a vacuum cleaner,
or by washing the fi lter in a solution of mild detergent and warm water.
If you wash the fi lter, be sure to allow it to dry thoroughly in a shady
place before reinstalling.
● If dirt is allowed to accumulate on the air fi lter, airfl ow will be reduced,
lowering operating effi ciency and increasing noise.
● During periods of normal use, the Air Filters should be cleaned every
two weeks.
● When used for extended periods, the unit may accumulate dirt
inside, reducing its performance. We recommend that the unit be
inspected regularly, in addition to your own cleaning and care. For
more information, consult authorized service personnel.
● When shutting down the unit for one month or more, fi rst allow the
fan mode to operate continuously for about one-half day to allow
internal parts to dry thoroughly.
2
1
3
AIR FILTER
PANEL
Air cleaning fi lter installation
1. Open the Intake Grille and remove the Air fi lters.
2. Install the Air cleaning fi lter set (set of 2).
Set the air cleaning fi lter into the panel.
Catch it on 5 places of picks.
(3 places of upper parts and lower part 2 places.)
3. Install the two Air fi lters and close the Intake Grille.
● When air cleaning fi lters are used, the effect will increased by setting
the fan speed to "High".
Replacing dirty air cleaning fi lters
Replace fi lters with the following components (purchased separately).
● APPLE-CATECHIN FILTER: UTR-FC03-2
● ION DEODORIZATION FILTER: UTR-FC03-3
1. Open the Intake Grille and remove the Air fi lters.
2. Replace them by two new Air cleaning fi lters.
(1) Remove the old air cleaning fi lters in reverse order of their installation.
(2) Install in the same way as for installation of the air cleaning fi lter set.
Air cleaning fi lter