Drainvac COMMERCIAL AE3200-CT 소유자 매뉴얼 - 페이지 14
{카테고리_이름} Drainvac COMMERCIAL AE3200-CT에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Drainvac COMMERCIAL AE3200-CT 15 페이지.
Drainvac COMMERCIAL AE3200-CT에 대해서도 마찬가지입니다: 소유자 매뉴얼 (15 페이지)
WEEE GUIDELINES
This unit complies with the WEEE (Waste Electrical and
Electronic Equipment) Guidelines, which promote the
recycling of this type of waste equipment and encourage the
development of products that are adapted to efficient waste
reclamation at the end of their life cycle.
The WEEE Guidelines stipulate that the original supplier should
agree to reclaim any obsolete equipment free of charge. We
recommend that you advise your supplier that you would like
him to reclaim your unit when you order and replace it with a new one.
Do not discard the unit with your regular garbage. The symbol representing a garbage
bin on wheels on the unit's label (Figure C) attests to this requirement. You must
ensure that, at the end of its life cycle, your unit is reclaimed, treated and recycled by
an authorized retailer or firm.
For more information, contact your municipal waste management department.
RoHS
All presented units respect the European directive RoHS which limits the usage of
six dangerous substances.
SUPPORT
If you wish to speak with a customer service representative, please contact your
supplier/dealer.
To find a retailer near you, please visit our website .
26
THE UNIT WON'T START UP...
SOLUTION :
1) Check if the LED is lit.
2) Check the circuit breaker in your electrical panel.
3) Check the unit's circuit fuse/breaker.
4) Check the 24-volt circuit, as follows :
Figure C
Establish an electrical contact between the two 24V circuit terminals of the unit with a
metal object such as a screwdriver or a coin.
• If the unit starts up, either the 24V wire is cut or disconnected from one of the
wall inlets, or the hose is defective.
• If the unit does not start up after all theses steps, the printed circuit is defective.
THE UNIT WON'T SHUT DOWN...
SOLUTION :
Check the 24-volt circuit as follows :
Disconnect one of the two wires on the unit's 24-volt circuit.
• If the unit shuts down, the problem could be that two 24-volt wires are touching
themselves somewhere or that the wall inlet is defective.
• If the unit doesn't shut down, the printed circuit is defective.
Unplug the power cord.