P
ROBLEM
Unit will not run
Pump will not prime
Incorrect volume
Charger "Fault" signal
Chemdose Troubleshooting
C
AUSE
Battery not charged
Blown fuse
Switch or timer settings
incorrect
In line strainer clogged
Leak in suction side of
pump
Inlet tubing restricted or
kinked
Debris in pump valves
Damaged pump valves
Check battery charge
level
Clogged nozzle
Confirm the correct
timer setting
Improper voltage
Damaged Battery
Charger
Fully charge battery
Check for cause and
repair, then replace fuse
Review manual operat-
ing procedures
Remove strainer bowl
and clean filter
Check all connections
and repair any leaks
Disassemble pump and
clean out debris
Disassemble pump and
replace valves
Recharge battery
Disassemble, clean and
re-install
Check chart on unit
and step time
Use voltage adapter
Get a replacement
charger from Dramm
Chemdose Manual
R
EMEDY