1. It is recommended to run a gallon of fresh water through the unit after each use. With the
discharge ball valve open run the unit until the gallon of water has gone through the unit and
discharged out of the discharge hose.
2. Disconnect the air line from the air fitting and relieve any remaining pressure in the system by
having the discharge ball valve in the open position.
3. Close the discharge ball valve when all the pressure is relieved from the system.
1. Check for proper air pressure (60psi or more into unit, 60 psi on AG100).
2. Check air inlet filter for debris such as water, oil, or rust particles. Clean by pressing up on the
bottom of the filter.
3. Check for plugged strainer. Replace strainer if necessary, STRAINER MUST BE USED.
4. If wet foam/dry foam valve is open too far the pump will not cycle properly due to lack of air
pressure. If this occurs, reset valve as described in operation instruction #4.
5. Make sure proper foaming chemical and concentration is being use.
6. If air passes through the pump without cycling, replace pump.
7. If foam solution backs up into air filter the check valve needs to be replace.
8. If foam comes out wet no matter where the wet foam/dry foam valve is positioned the check valve
may need to be replaced.
9. If unit foams at a reduced pressure:
A. Check the air supply into the unit. If it is low, turn th foam unit off until the compressor
can catch up.
B. If the air supply is 60psi or above, check the internal air gauge which should read near
60psi. If the gauge is more or less than 60psi, adjust the pressure by turning the know on
the top of the regulator.