Ambassador Projection Screen by Draper
1
10
/
"
4
10"
Standard
Offset
Extended Hinges
Construction
Construction
for Attachment of
Ceiling Tile
(Wt. not to exceed
16 oz. per sq. ft.)
Junction box at
left end of screen
To 110-120v Line
Control
Switches
24 VDC
Case Dimensions
4"
Rods and
attaching
hardware
by others
Mtg. bracket
by Draper
Surrounding
ceiling
Ceiling tile
(by others)
Conduit connection
this side
Wiring Diagrams
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by installer
Single gang box by others
Control
Min. 4" x 2 1/8" x 1 7/8" deep
switch
Blue
Red
Black
Location of key
operated on-off
switch if furnished
Low Voltage (& Wireless) Control Wiring Diagram
Low Voltage Control Module
Black (DN)
Black (DN)
Red (UP)
Red (UP)
STOP
White (COM)
White (COM)
Black (DN)
Red (UP)
STOP
White (COM)
Optional
Radio
Receiver
Package
Fabric width + 24"
Motor compartment
and grid
Viewing
surface
3
19
/
"
8
Multiple Station Control
Junction box at
left end of screen
Motor
Red
Black
Red
Black
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120v Line
Black
White
Red
White
Red
Brown
Black
Yellow
Green
Optional Infrared
Dotted wiring by installer
Receiver Package
Location of key
operated on-off
switch if furnished
To 110-120V Line
Mounting brackets
Internal Screen Wiring
White (Common)
Black (Down)
Motor
Red (Up)
Green (Ground)
Cap off with wire
nut and tape
Blue
Dashed wiring
by installer
Blue
Blue
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.
Internal Screen Wiring
White (Common)
Red (Up)
Black (Down)
Green (Ground)
Page 2 of 2
7
9
/
"
8
5"
5
4
/
"
8