4.

INTRODUCTION

4.1 SCOPE

This torque wrench is used to apply a specific torque to a fastener such as a nut or bolt.

4.2 SPECIFICATION

Stock no. ....................................72673 ................................. 72714 .....................................83317
Part no. ....................................... PTW.................................... PTW ........................................ PTW
Torque range ........................... 5-35Nm............................ 25-135Nm...........................50-225Nm
..................................................4-25lb/ft ...........................20-100lb/ft .........................40-160lb/ft
Accuracy .................................... +/- 4%................................ +/- 4%....................................+/- 4%
Square drive size .................... 1/4"+3/8" .............................3/8"+1/2".......................................1/2"
Overall length approx ............. 340mm .............................. 565mm ................................ 625mm
Manufactured and tested in accordance with to ISO 6789 Standards.
Whilst every effort has been made to ensure that the accuracy of information given in this manual
is correct at time of going to print, the Draper Tools policy of continuous improvement determines
the right to change specification without notice.
This torque wrench is accurate to ± 4% of the set load and has been manufactured and tested in
accordance to ISO 6789.
Torque tools are classified as test devices. If a calibration routine is required, the calibration
interval shall be chosen on the basis of the factors of operation such as required accuracy,
frequency of use, typical load during operation as well as ambient conditions during operation and
storage conditions. The interval should be decided according to the user's procedures for the
control of test devices and by the requirements of the user.
If the user does not use a control procedure, a period of use of 12 months, or approximately 5000
cycles can be taken as a default value of the recalibration interval. For the first recalibration,
the period of validity starts with user's first operation of the torque tool.
In addition to these specifications, factory or legal regulations shall be observed.
The torque tool shall be recalibrated when it has been subjected to an overload greater than 125%
of maximum rated load and after repair, or after any improper handling which might influence any
errors in measurement.
4.3 HANDLING & STORAGE
Ensure you have a good stable position whilst using this product. Care should be exercised when
using this product due to rotating parts etc.
Store the product together with this manual in its protective case in a cool dry place with the torque
wrench set to its minimum setting.
This product should be cleaned, maintained and lubricated regularly to ensure it is operating at
peak performance.
5