Draper DA200/300B 사용 설명서 - 페이지 11
{카테고리_이름} Draper DA200/300B에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Draper DA200/300B 16 페이지. 100, 150 & 200 litre compressors
It is advisable to clean all the finned parts of
your compressor, so as to keep the cooling
system efficient and to ensure a long work
life to your machine. Check belt tension.
Hang a weight of about 3kg at the midpoint of
the belt. The belt should flex about 10mm.
(Fig.11).
If necessary, tension up the belt taking care
not to disturb the pulley-to-flywheel
alignment (Fig.12).
OPERATIONS TO BE CARRIED OUT
EVERY 2 YEARS:
Check the non-return valve and if necessary
replace the seal.
Check intake and delivery valves on valve
plates.
Recommended Oils:
Recommended oils with ISO 100 viscosity for
compressors, in accordance with DIN51506-
VDL 100-E Standards and ISO6521:L-DAC
Specifications (suitable for room temperature
ranging from +6°C and +25°C).
AGIP
DICREA100
API
CM-8X
BP
ENERGOL CS100
CASTROL
AIRCOL PD100
ESSO
EXX OLUB H150
IP
CALATIA OIL ISO 100
MOBIL
RARUS 427
FINA
EOLAN AC 100
SHELL
COREMA OIL H100
TOTAL
CORTUSA 100
Use oils with an ISO 46/68 viscosity for a
room temperature ranging from 0°C to + 5°C
Use oils with an ISO 150 viscosity for a room
temperature ranging from + 26°C to + 45°C.
MAINTENANCE
Fig.11.
Fig.12.
- 10 -