Draper FlexShade 2 Pocket Headbox 사용 설명서 - 페이지 7

{카테고리_이름} Draper FlexShade 2 Pocket Headbox에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Draper FlexShade 2 Pocket Headbox 8 페이지. Maximized coverage for large, tall areas, while also reducing light gap

Draper FlexShade 2 Pocket Headbox 사용 설명서
FlexShade
Section 8 - Components, Wiring and Controls
Controls & System Overview
Sonesse
®
120V
MOTOR
M12
Connector
W B R G
Control
Switch
Single Gang
B
Box (by others)
110-120V Line
Controls & System Overview
Sonesse
485 120VAC Motors
®
Bus Power
Supply
LAN
BUS IN
MOTOR Pin-Out - RJ9 Connector
RS485
RS485
110VAC
110VAC
Motor
Motor
M12
Connectors
110-120V Line
110-120V Line
2 Pocket Headbox
®
120VAC Motors
NOTE: Test shade operation
If shade direction does not
correspond with the switch
orientation, turn power back
off and switch the red and black
wires from the motor to the switch.
Do not wire motors in parallel without
written permission from Draper.
Dashed Wiring
by Electrician
110V
Outlet
Data Hub
BUS OUT
to next
DATA HUB
4 - GROUND - (BROWN)
3 - POWER + (BLUE)
2 - DATA - (ORANGE)
1 - DATA + (ORANGE/WHITE)
STOP
Wall Switch
Data Cable
with RJ45
Connector
Dashed Wiring
by Electrician
Controls & System Overview
Sonesse
RTS 120VAC Motors
®
RTS
MOTOR
120V
M12 Connector
B W G
110-120V Line
MOTOR Pin-Out - RJ9 Connector
Data Cable Pin-Out - RJ45 Connector
1 - DATA + (ORANGE/WHITE)
2 - DATA - (ORANGE)
3 - N/A (GREEN/WHITE)
4 - POWER + (BLUE)
5 - POWER - (BLUE/WHITE)
6 - N/A (GREEN)
7 - GROUND - (BROWN/WHITE)
8 - GROUND - (BROWN)
Telis 1
RF Remote
STOP
Deco Flex
Wireless Keypad
Dashed Wiring
by Electrician
4 - GROUND - (BROWN)
3 - POWER + (BLUE)
2 - DATA - (ORANGE)
1 - DATA + (ORANGE/WHITE)
page 7 of 8