Draper Motorized FlexShade 사용 설명서 - 페이지 9
{카테고리_이름} Draper Motorized FlexShade에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Draper Motorized FlexShade 12 페이지. Motor operated window shades with several control options
Draper Motorized FlexShade에 대해서도 마찬가지입니다: 설치 및 작동 지침 (8 페이지)
Motorized FlexShade
Section 7 - Attaching Fascia to Endcaps
Please Note:
- Endcaps must be installed the correct
distance apart for fascia to be properly
attached with full engagement.
STANDARD ROLL FASCIA
STANDARD ROLL FASCIA
1.
Place groove
along top of
fascia over
endcaps.
STANDARD ROLL FASCIA
STEP 1:
ENDCAP
2.
Snap into
place.
Section 8 - Limit Switch Adjustments
Standard and Quiet Motors
Push Button Limits
1. Fully depress both limit switch push buttons, then
operate wall switch to make sure system works properly.
2. Raise shade to desired "up" stop position.
3. Set upper limit by depressing proper
4. Lower shade to desired "down" stop position.
5. Set lower limit by depressing proper
Screw-Type Limits
1. Determine which direction of fabric travel corresponds
with arrows on motor.
2. Operate shade to desired "down" stop position.
Set limit by turning proper socket toward
-
and
to raise it.
3. Operate shade to desired "up" stopping position. Set limit by
turning proper screw toward
Limit Switch Adjustments:
RS485 Motors:
See limit setting instructions
packaged with the RS485 Address/
Limit Setting Tool
(part# C156.241)
Section 9 - Electrical Connections
Shade operates on 110-120V, 60 Hz. current. Shade is shipped with internal wiring complete and control switch
cable lead. Longer lead can be substituted by removing two screws in motor end of roller, removing lead, plugging new lead in, and replacing screws. Wire to connect
shade to switch
and switch
(es)
Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in
parallel without written permission from Draper
All operating switches should be "off" before power is connected.
Please Note: For low-voltage wiring requirements, Draper recommends consulting with a professional low-voltage electrical contractor. It is very important that
shielded and stranded CAT 5 cable be used to prevent any electrical interference.
Please Note: A Draper Motor Test Cable
IMPORTANT: To reduce the risk of electric shock, equipment that features a grounding type attachment plug has a third
This plug will ONLY fit into a grounding type outlet. If the plug does not fit into the outlet, a qualified electrician must install the proper outlet.
DO NOT change the plug in any way.
DO NOT use an extension cord. If the power supply cord is too short, a qualified electrician must install an outlet near the drapery operator.
®
REVERSE ROLL FASCIA
REVERSE ROLL FASCIA
STEP 2:
STEP 1:
1.
REVERSE ROLL FASCIA
Slide endcap
STEP 1:
ENDCAP
ENDCAP
onto fascia.
REVERSE ROLL FASCIA
STEP 1:
STEP 1:
Clicks into place
STEP 2:
ENDCAP
Clicks into place
(All procedures shown are for Standard Roll. Invert orientation for Reverse Roll)
push button.
(back)
push button.
(front)
+
to lower limit,
-
+
to raise limit, and
to lower it.
RTS Motors:
See Radio Frequency Remote
Control Programming Instructions
.
.
(FS_MO_RFRC_ProgInst)
to power supply should be furnished by installer.
(es)
.
®
and M12 Pigtail
(Part# 503109)
(Coupled)
- Fascia is not fully seated
until it clicks into place
on both ends.
2.
Hang fascia
on room side
STEP 2:
of endcap.
STEP 2:
Caution:
-
Be sure all switches are in "off"
position before adjusting limit
switches.
- Be prepared to shut off
manually while testing.
- Shade may be damaged by
running shade fabric down too
far to expose roller.
- If using a group control system,
each limit switch must be set
prior to connecting to system.
- Motor must be installed so limit
switches are pointed down.
IntelliFlex I/O Motors:
See limit setting instructions
packaged with the Motor Limit
Setting Tool
(part# C202.030)
are available for temporary power for testing and limit setting.
(Part# C107.089.60)
- Once in place, check for secure fit.
If not secure, use an appropriate
fastener
(not included)
3.
Slide Clip to end of fascia, ensuring that
clip covers mounting bracket of endcaps.
STEP 2:
STEP 3:
STEP 3:
R O
L L E
R O
R
L L E
R
S L
I D E
S L
S L
I D E
I D E
ROOM SIDE
Tighten
Tighten
set screw
set screw
with included
4.
with included
Hex Wrench.
Hex Wrench.
PUSH BUTTON LIMITS
GLASS SIDE
ROOM SIDE
ROOM SIDE
Front
Back
GLASS SIDE
Bottom View
SCREW-TYPE LIMITS
GLASS SIDE
ROOM SIDE
+
Front
Side View
Back
+
GLASS SIDE
Bottom View
.
fully boxed, and standardly supplied with a 6'
(es)
Screws
Side View
pin on the attachment plug.
(grounding)
page 9 of 12
.
STEP 3:
R O
A kit containing two
L L E
clips and a hex wrench
R
is supplied per
Reverse Roll
each piece
Fascia Clip Kit
of fascia.
Tighten
set screw
with included
Front
Tighten set-screw with
Hex Wrench.
included Hex Wrench.
Back
Standard right-hand
motor configuration shown
Bottom View
+
Front
Back
+
Side View
Standard right-hand
Bottom View
motor configuration shown
Screws
Side View
(1.8 m)