Drawell T60 사용 설명서 - 페이지 7
{카테고리_이름} Drawell T60에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Drawell T60 17 페이지.
1.1 Summarize
TSVP® T SERIES VACUUM PUMP
number shows in the model(8,16,30,60) means the pumping speed, unit m
TSVP® T SERIES VACUUM PUMP
corrosive gas.
1.2 Working Theory
As shown in fig.1 functional diagram:
The rotor, mounted eccentrically in the pump cylinder,has 2 vanes which divide the pump chamber into two
different changeable compartments.
When the pump rotor which was driven by the motor clockwise rotated, chamber 1 will such air from small to
big, and chamber 2 will complete the transmission of air, then chamber 3 will compress and exhaust air from big to
small, and complete a work cycle from suction-compress-exhaust finally, achieve the vacuum of the system.
1.3 Lubrication
We will equip the pump oil along with the pump, TPO-68
If you want to buy additional pump oil, please contact with our sales department
1.4 Configuration
All the pump will be equipped with the motor:
Single phase can be start instantly
Three phase motor should be connected by a skilled electrician.
Below items will be delivered along with the pump:
Operation instruction---1copy
Clamp(KF25 or KF40)---2pcs
Pump Oil---1bottle
is the double stage oil sealed rotary vane vacuum pump,the
/h
3
can only pump the gas,and not suitable with harmful gas or
(fig. 1)
6