AirStage AUXD18GALH 운영 매뉴얼 - 페이지 3

{카테고리_이름} AirStage AUXD18GALH에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AirStage AUXD18GALH 6 페이지. Indoor unit (cassette type)
AirStage AUXD18GALH에 대해서도 마찬가지입니다: 설치 매뉴얼 (17 페이지)

AirStage AUXD18GALH 운영 매뉴얼

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is
lost or otherwise unavailable.
CAUTION
Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.
Starting Operation
Press the MANUAL AUTO button on the operating
control panel.
The operation can be set in the following setting.
Operating mode
AUTO:
When Auto mode cannot be selected, it will
operate in the same mode as the other indoor
unit in the same system. (When other indoor
unit in the same system doesn't operate, the air
conditioner will operate in cooling.)
Fan speed
AUTO
Setting temperature
23 °C
Stopping Operation
Press the MANUAL AUTO button on the operating
control panel.
ADJUSTING THE DIRECTION OF
AIR CIRCULATION
The vertical wind direction can be controlled with the control unit.
Vertical direction
Cooling & Dry : (1), (2), (3), (4)
Heating :
(1), (2), (3), (4)

OPERATING TIPS

Operation and Performance
About priority state and standby state
● Multiple indoor units can be connected within the same system. De-
pending on the system, choice of operating mode are limited.
Cooling priority state:
When the other indoor units within the same system operate in cooling
or dry mode, heating can not be selected at the same time.
Heating priority state:
When the other indoor units within the same system operate in heating
mode, cooling and dry mode can not be selected at the same time.
Standby state:
The standby state activates when 2 or more indoor units start up at the
same time in different mode. Any indoor unit other than priority mode
will wait in standby state until priority mode changes (operation starts
as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) lights up and the
TIMER indicator lamp (orange) fl ashes.
Low ambient cooling
● When the outdoor temperature drops, the outdoor unit's fans may
switch to Low Speed, or one of the fans may stop intermittently.
AMP Air Conditioning
Heating performance
● Heating mode operates on the heat-pump principle, absorbing heat
from outdoor air and transferring that heat indoors. As a result, the
operating performance is reduced as outdoor air temperature drops.
If you feel that insuffi cient heating performance is being produced, we
recommend you use this air conditioner in conjunction with another
type of heating appliance.
● Heating mode heat your entire room by recirculating air throughout the
room, with the result that some time may be required after fi rst starting
the air conditioner until the room is heated.
Microcomputer-controlled automatic defrosting
● When using the Heating mode under conditions of low outdoor air
temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner
will temporarily stop, and the defrosting circuit will operate briefl y (for
about 4 to 15 minutes).
During Automatic Defrosting operation, the OPERATION indicator
lamp (green) will fl ash.
Oil recovery operation
● Periodically, the oil recovery operation is performed in order to return
compressor oil to the outdoor unit. During oil recovery operation, the
OPERATION indicator lamp (green) will fl ash (for about 10 minutes).
Temperature and humidity range
● The temperature and humidity required for operating this product is as
shown in the following table.
Outdoor
temperature
Indoor
temperature
Indoor humidity
● If the air conditioner is operated under higher temperature conditions
than those listed, the built-in protection circuit may operate to prevent
internal circuit damage. Also, during Cooling and Dry modes, if the unit
(1)
is used under conditions of lower temperature than those listed above,
(2)
the heat-exchanger may freeze, leading to water leakage and other
(3)
damage.
(4)
● If the unit is used for long periods under high-humidity conditions,
condensation may form on the surface of the indoor unit, and drip onto
the fl oor or other objects underneath.
● Do not use this unit for any purposes other than the Cooling, Heating,
Dehumidifying, and air-circulation of rooms in ordinary dwellings.

CLEANING AND CARE

● Before cleaning the unit, be sure to stop the unit and disconnect the
power supply.
● Do not stand on an unstable platform when cleaning.
● When removing and replacing the air fi lters, be sure not to touch the
heat exchanger, as personal injury may result.
● Be sure the intake grille is installed securely.
● Do not clean the inside of the unit by yourself. To clean the inside,
always consult authorized service personnel.
● When cleaning the unit's body, do not use water hotter than 40 °C,
harsh abrasive cleansers, or volatile agents like benzene or thinner.
● Do not remove any part from the unit except for the fi lter.
● If dirt is allowed to accumulate on the Air Filter, airfl ow will be reduced,
lowering operating effi ciency and increasing noise.
● AUXB 04/07/09/12/14/18/24 During periods of normal use, the air
fi lters should be cleaned every 2 months.
● AUXD 18/24, AUXA 30/34/36/45/54 During periods of normal use, the
air fi lters should be cleaned every 2 months.
Cooling/Dry Mode
Please refer to the specifi cation of outdoor units.
18 to 32 °C DB
About 80% or less
CAUTION
www.ampair.co.uk | [email protected]
Heating Mode
10 to 30 °C DB
En-2