OPERATION
To set the operation mode
● Economy setting
● Vertical air direction adjustment (Swing operation/Louvre position)
● Horizontal air direction adjustment (Swing operation/Louvre position)
NOTES
(1) • Always use the remote controller's AIRFLOW DIRECTION
button. Attempting to move the air direction louvers
manually could result in improper operation; in this case,
stop operation and restart.
The louver should begin to operate properly again.
• During cooling operation, do not set the vertical airflow
direction louver in the downward position for an ex-
tended period. Water vapor may condense near the out-
let port and drops of water may drip from the air condi-
tioner.
(2) • The range of swing is relative to the currently set airflow
direction.
• The SWING operation may stop temporarily when the
air conditioner's fan is not operating, or when operating
at very low speeds.
(3)
The swing operation is not available depending on the
model. Please refer to the operating manual for the in-
door unit.
En-3
Press the ECONOMY button to start or stop the energy-
saving air conditioner operation.
* The energy save air conditioner operation is not available
depending on the model.
* Press the START/STOP button to set the air conditioner in the operation mode.
Then, proceed with the following steps.
Press the VERTICAL AIRFLOW DIRECTION button. The temperature display will
change to the vertical airflow direction setting display.
Press the VERTICAL AIRFLOW DIRECTION button to change the vertical louvre posi-
tion. The position number will appear on the display.
Press and hold the VERTICAL AIRFLOW DIRECTION button for 2 seconds or more to
set the swing operation ON or OFF.
The flashing display indicates that
the swing operation is OFF.
* Press the START/STOP button to set the air conditioner in the operation mode.
Then, proceed with the following steps.
Press the HORIZONTAL AIRFLOW DIRECTION button. The temperature display will
change to the horizontal airflow direction setting display.
Press the HORIZONTAL AIRFLOW DIRECTION button to change the horizontal lou-
vre position. The position number will appear on the display.
Press and hold the HORIZONTAL AIRFLOW DIRECTION button for 2 seconds or more
to set the swing operation ON or OFF.
The flashing display indicates that
the swing operation is OFF.
<Vertical airflow swing operation>
Airflow direction
Range of swing
1
2
1 to 4
3
(All range)
4
<Horizontal airflow swing operation>
Airflow direction
Range of swing
1
2
1 to 5
3
(All range)
4
5
1
2
3
4
1 2
4 5
3