When planning your site layout and equipment loations, remamber the precautions described in the
next section ,"Preventive Site Configuration" .If you are experiencing shutdowns or unusually high
errors with your exsting equipment, this precautions might help you isolate the cause of failures and
prevent future problemss.
2.2.2

Preventive site configuration

The following precautions will help you plan an acceptable operating environment for you switch and
help you avoid environmentally-cauesd equipment failures:
11. Ensure that the room in which you operate your system has adequate air
12. Always follow the EDS-prevention procedures to avoid damage to
13. The chaissis is designed to allow cooling air to flow effectively inside it .An
2.2.3

Configuring Equipment rack

The following information will help you plan an acceptable equipment rack configuration.
14. The equipment in the rack will heat when working.So enclosed racks must
15. When mounting a chassis in an open rack ensure that the rack frame does
16. Ensure that you provide adequate ventilation for equipment at the bottom of
17. Baffles can help to isolate exhaust air from intake air, which also helps to
2.2.4

Power supply condition

Check the power at you site to ensure that you are reaieving "claen" power.Install a power conditioner
if neccesary.nsure that a fuse or circiut breaker no larger than 240V,10A interminal is used on the phase
conductors.
Warning:
If the power system does not connect to the earth properly , the variables of input power is big or exist
excess pulse,it will add error ratio of communication equipment ,even to damage the hardware system.
circulation .Electrical euqipment generates heat .Ambient air temperature
might not be able to cool equipment to acceptable opoerating temperatures
without adequate circiulation.
equipment .Damage from static discharge can cause immediate or
intermittent equipment failure.
open chassis allows allows air leaks ,which might interrupt and redirect the
flow of cooling air from internal components.
have adequate ventilation.The equipment should not be put too close to
each other to ensure the racks are not overheat.
not lock the intake or or the exhaust ports.So check the position of the
chassis when it is seated all the way into the rack.
rack.
draw cooling air through the chassis .The best placement of the chassis on
the airflaw in the rack ,which and be found by experimenting with different
arrangement.