GUN MOUNTING
A hexagon screw (13) will secure the spray gun to the 54-380
gun mounting rod. For special mountings, a 1/2" dia. rod will fir
the hole in the top of the gun body.
HOSE LENGTH
Install minimum hose length from valve to gun to minimize time
required for "off–on" response of gun.
CONNECTIONS
The air connection and fluid connection are both 1/4 NPS. The
air connection is stamped "a".
AIR SUPPLY
Since the gun has its own control, atomizing air may be taken
directly from the main line. However, if regulated air is used, 50
PSI minimum is required to actuate gun fluid valve piston. When
rapid "off–on" operation is required, use a 3-way valve which
exhausts to atmosphere, in place of a 2-way valve.
SPRAY PATTERN
The width of spray pattern is controlled by the control assembly
(26). Vertical or horizontal position of the spray is obtained by
rotating the air nozzle.
ATOMIZATION
Air volume to the nozzle is controlled by the control assembly
(26) located adjacent to the air inlet connection.
FLUID CONTROL
The rate of fluid flow is controlled by a combination of the
selection of the correct nozzle orifice size and adjustment of fluid
pressure. The maximum fluid flow rate is approximately 8 fluid
ounces per minute. Fine adjustment of the fluid flow can be
obtained by controlling the travel of the needle valve. Clockwise
rotation of the screw (24) decreases the needle travel and coun-
terclockwise rotation increases the travel. The locknut (15) is
used to lock the screw (24) after adjustment.
Binks MODEL 460 GUN FLUID NOZZLE, NEEDLE & AIR CAP SELECTION CHART
Fluid Nozzle
Orifice Size
J920SS
.020"
(PN 45-84)
(.5 mm)
J930SS
.030"
(PN 45-85)
(.75 mm)
J940SS
.040"
(PN 45-86)
(1.0 mm)
J940SS
.040"
(PN 45-86)
(1.0 mm)
K960SS
.060"
(PN 45-87)
(1.5 mm)
*Spray pattern for reference only. Pattern size will vary slightly with flow and viscosity of the materials.
www.carlisleft.com
INSTALLATION, OPERATION & MAINTENANCE
Fluid Needle
Air Nozzle
940
J92P
(PN 47-454)
(PN 46-131)
940
J92P
(PN 47-454)
(PN 46-131)
940
J92P
(PN 47-454)
(PN 46-131)
940
J92R
(PN 47-454)
(PN 46-126)
960
K92P
(PN 47-455)
(PN 46-134)
FAULTY SPRAY
Caused by improper cleaning, or dried fluid on nozzle tip or in
the air nozzle. Soak these parts in solvent to soften the dried
fluid and remove with a brush or cloth.
CAUTION
!
Never use metal instruments to clean air or fluid nozzles.
These parts are carefully machined and any damage to
them will cause a faulty spray.
If either air nozzle or fluid nozzle is damaged, the part must be
replaced before a perfect spray can be obtained.
SPITTING
To eliminate spitting and dripping, turn on atomizing air before
turning on fluid.
NEEDLE ADJUSTMENT
The correct setting is to allow approximately 1/16" piston travel
before contacting NEEDLE. Adjustment is made by loosening the
screw (17) on rear of needle and rotating the spring guide (20)
either forward to reduce or back to increase clearance.
AIR LEAKAGE INTO AIR CYLINDER VENT
Remove piston (19) and inspect for dirt or damage to large
o-ring (5). Clean piston and cylinder. Replace o-ring if necessary.
Lubricate with white petroleum jelly.
AIR LEAKAGE AT FLUID NEEDLE
Remove piston (19) and inspect for dirt or damage to small
o-ring (6). Replace if necessary.
FLUID LEAKAGE AT PACKING GLAND
Tighten screw (10) and slightly "back-off" screw to set packing. If
leakage continues, replace packing.
CLEANING THE GUN
Under no circumstances should the complete gun be immersed
in thinners or solvents.
Approx. Air Consumption
SCFM with Specific Dynamic
Air Presure (PSI) at air cap
30 PSI
50 PSI
70 PSI
6.4
8.5
10.5
6.4
8.5
10.5
6.4
8.5
10.5
4
6
8
7.2
10.6
14
4 / 8
Type of
*Max. Spray
Spray
Pattern Size @
Pattern
5" Distance
ELLIPSE /
6"
STRAIGHT SIDES
ELLIPSE /
7.5"
STRAIGHT SIDES
ELLIPSE /
8"
STRAIGHT SIDES
ROUND
2"
ELLIPSE /
9.5"
STRAIGHT SIDES
77-2019-R6 (12/2020)