Installation
This product should be flushed with a suitable compatible solvent prior to use.
Mount the pump securely and position the pump at a convenient height (below the lid height of the
paint container), to allow for maintenance, visual observation, and periodic inspection.
The wall mount bracket is included with all pumps.
The Pump Mounting bracket must be connected to a suitable earth ground to ensure that there is no
possibility of static build up.
Attach suitable flexible hoses to the inlet and outlet connections.
Connect a suitable 3/8" NB air hose and 1/2" Pressure Filter Regulator to the air motor.
(Filter rated at minimum 1000 l/min)
No additional air lubrication is required as piston ring lubricant is applied during assembly or repair.
If an air lubricator is used then, this must be maintained.
77-3233 R4.3
6/20
www.carlisleft.com