How to remove Color Change Valve (CCV) using the CCV-7 Valve Tool:
77-3117 & 77-3118 updates
HOW TO INSTALL COLOR CHANGE VALVE (CCV) USING THE CCV-7 VALVE TOOL:
CS-15-10 update:
HOW TO INSTALL COLOR CHANGE VALVE (CCV) USING THE CCV-7 VALVE TOOL:
3
77-3118-R3 (9/2018)
CCV-7 VALVE TOOL
ACCESSORIES
1
2
Item
No.
1
2
3
4
4
7 / 8
When installing the CCV valve assembly into a manifold
block, DO NOT use pipe sealant or PTFE tape.
The CCV valve must be supported while tightening the
tube fittings to prevent damage to the valve seats,
if installed in a manifold. Or you may remove the valve
before tightening the fluid inlet fittings.
14.9-17.6 N-m
[132-156 in-lbs]
MAX.
When installing the CCV valve assembly into a manifold
block, DO NOT use pipe sealant or PTFE tape.
The CCV valve must be supported while tightening the
tube fittings to prevent damage to the valve seats,
240-5004 Air Push Regulator Kit
if installed in a manifold. Or you may remove the valve
before tightening the fluid inlet fittings.
Part No.
Description
A10857-00
AIR REGULATOR
SSP-1421
PIPE PLUG
14.9-17.6 N-m
[132-156 in-lbs]
GA-338
BACK MOUNT GAUGE (0-160 PSI), 1½" DIA
MAX.
SSV-809
CHECK VALVE
IMAGE SHOWS LEFT SIDE CONFIGURATION.
REVERSE ITEMS 2 & 3 FOR RIGHT SIDE.
EN
Qty.
1
1
1
1