Dražice OKC 200 NTRR / BP 작동 및 설치 매뉴얼 - 페이지 19

{카테고리_이름} Dražice OKC 200 NTRR / BP에 대한 작동 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dražice OKC 200 NTRR / BP 20 페이지. Stationary water heaters
Dražice OKC 200 NTRR / BP에 대해서도 마찬가지입니다: 작동 및 설치 매뉴얼 (17 페이지), 작동 및 설치 매뉴얼 (12 페이지), 작동 및 설치 매뉴얼 (19 페이지), 작동 및 설치 매뉴얼 (20 페이지), 작동 및 설치 매뉴얼 (18 페이지), 운영 및 설치 매뉴얼 (20 페이지), 작동 및 설치 매뉴얼 (18 페이지), 운영 및 설치 매뉴얼 (13 페이지)

Dražice OKC 200 NTRR / BP 작동 및 설치 매뉴얼
To limit regulation
off the thermostat knob (it will be tough at first) and you will find two cylindrical pins Ø2,15mm on
-
the back side of the knob
pull off one pin and insert it to the corresponding hole of the selected maximum temperature.
-
put the knob back on (to the stop).
-
To block the setting
set the selected temperature pull off the thermostat knob without changing the setting, there are
-
two pins on the back side of the knob
Pull off both of them and fit them to the holes corresponding with the selected temperature so that
-
the gap between the pins was without a hole, and the position was opposite the set temperature.

4 IMPORTANT NOTICES

4.1 INSTALLATION REGULATIONS

Without a confirmation of performed electrical installation issued by an authorised company, the
-
warranty certificate shall be void.
Check and exchange the Mg anode regularly.
-
You have to apply for approval of a local power supplier to connect the heater.
-
No stop valves can be put between the heater and the safety valve.
-
If the overpressure in the water main exceeds 0.48 MPa, a pressure control valve must be mounted
-
before the safety valve.
All hot water outputs must have a combination faucet.
-
Before filling the heater with water for the first time, it is recommended to fasten the flange
-
connection nuts of the tank.
It is not allowed to handle the thermostat, aside from temperature resetting with a control button.
-
All electric installation handling, adjustment and replacement of the regulation elements shall only
-
be performed by an authorised service company.
The thermal fuse must not be turned off! In case of thermostat defect, the thermal fuse interrupts
-
electric power input to the heating element if the water temperature in the heater exceeds 90 °C.
As an exception, the thermal fuse may also switch off due to water overheating caused by
-
overheating the hot water heating system boiler (in case of a combined heater).
We recommend you operate the heater with one type of energy.
-
Both the electric and water installation must follow and meet the requirements and
regulations relevant in the country of use!
Figure 9
- 19 -