Drazice OKCE 125 -2/6 kW 운영 및 설치 매뉴얼 - 페이지 16

{카테고리_이름} Drazice OKCE 125 -2/6 kW에 대한 운영 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Drazice OKCE 125 -2/6 kW 19 페이지. Tank-type water heater for vertical mounting

Drazice OKCE 125 -2/6 kW 운영 및 설치 매뉴얼
We recommend checking and cleaning the tank from lime scale and eventual replacement
of the anode rod after two years of operation. The anode life is theoretically calculated
for two years of operation; however, it changes with water hardness and chemical composition
in the place of use. Based on such an inspection, the next term of anode rod exchange may
be determined. If the anode is only blocked with sediments clean its surface and, if used up,
mount a new one. Have a company in charge of service affairs deal with the cleaning
and exchanging of the anode.

2.9 MOST FREQUENT FUNCTION FAILURES AND THEIR CAUSES

FAILURE SYMPTOM
Water is cold
Water is cold
Water is not warm
enough
Temperature of water is
not corresponding with
the temperature set on
the control
Water is constantly
dripping off the safety
valve
Do not attempt to repair the failure yourselves. Seek either expert or service help. It does not
take much for an expert to remove the defect. When making a repair appointment, report
the type and serial number you find on the performance plate of your water heater.
INDICATOR
Light on
Light off
Light on
Light off
Table 4
SOLUTION
low temperature set
on the thermostat
heating element failure
No supply voltage!
Thermostat failure
Safety thermostat shut off
probably due to failed
operation thermostat
failure of one of the coils
in the element (3 x 1100W)
Defective thermostat
high input pressure
defective safety valve
- 16 -