1.3 DESIGN AND GENERAL DIMENSIONS

The storage tank vessel is made of a steel plate and tested by 0.9 MPa overpressure. The inside of the
vessel is enamelled. A flange is welded onto the upper bottom of the receptacle with a flange lid is screwed
to it. A sealing ring is inserted between the flange lid and the flange. Thermowells for thermostat sensors
and thermometer installation are placed in the flange lid. Anode rod is mounted on M8 nut. The water
reservoir is insulated by means of polyurethane foam. Electric wiring is placed underneath the plastic
removable cover. The temperature of water can be set using the thermostat. Heat exchanger is welded in
the pressure tank.
Technical description: OKH 100 NTR, OKH 125 NTR, OKH 160 NTR
Figure 1
Technical desription: OKH 100 NTR/HV, OKH 125 NTR/HV
Figure 2
1 Thermometer
2 Enamelled steel receptacle
3 Storage tank shell
4 Polyurethane freon-free insulation
5 Tubular heat exchanger
6 Discharge outlet
7 Cold water filling pipe
8 Circulation
9 Mg anode
10 Hot water drain pipe
11 Electric installation cover
1 Thermometer
2 Enamelled steel receptacle
3 Storage tank shell
4 Polyurethane freon-free insulation
5 Tubular heat exchanger
6 Discharge outlet
7 Cold water filling pipe
8 Circulation
9 Mg anode
10 Hot water drain pipe
11 Electric installation cover
- 5 -