Drazice OKC 200 NTRR/SOL 운영 및 설치 매뉴얼 - 페이지 9
{카테고리_이름} Drazice OKC 200 NTRR/SOL에 대한 운영 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Drazice OKC 200 NTRR/SOL 17 페이지. For solar systems
Drazice OKC 200 NTRR/SOL에 대해서도 마찬가지입니다: 작동 및 설치 매뉴얼 (12 페이지)
300 litre volume tanks are screwed onto the bottom wooden palette with M12 screws. When
the tank is released from the pallet and prior to its putting into operation, 3 screw legs supplied
have to be installed as the product accessories. With three adjustable legs, the tank may be
positioned vertically to the base within 10 mm range.
2 AND FITTING INSTRUCTIONS
2.1 OPERATION OPERATING CONDITIONS
The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for electric wiring. Besides the legally acknowledged national regulations
and standards, also conditions for connection defined in the local electric and water works
have to be adhered to, as well as the installation and operation manual.
The temperature at the place of the tank installation must be higher than +2°C; and the room
must not freeze. The appliance has to be mounted at a convenient place; it means that the
appliance must be easily available for potential necessary maintenance, repair or
replacement, as the case may be.
We emphasize that the tank shall not be connected to power supply if flammable liquids
(benzine, stain cleaner) or gases, etc., are handled in its proximity.
- 9 -