2 OPERATION AND FITTING INSTRUCTIONS
2.1 OPERATING CONDITIONS
The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for electric wiring. Besides legally acknowledged national regulations
and standards, also conditions for connection defined in local electric and water works have
to be adhered to, as well as the installation and operation manual.
The temperature at the place of heater installation must be higher than +2°C; and the room
must not freeze. The appliance has to be mounted at a convenient place, it means
that the appliance must be easily available for potential necessary maintenance, repair
or replacement, as the case may be.
If water is strongly calcareous we recommend that any of the common decalcifying devices
was installed with the appliance, or that the thermostat was set to the minimum operating
temperature of 60
operation, drinkable water of adequate quality shall be used. To avoid potential sediments we
recommend that the device was installed together with a water filter.
2.2 WALL MOUNTING
Prior to the mounting check the bearing capacity of the wall and the material it is made
of, considering the weight of the heater filled with water. Depending on the wall material choose
adequate fixtures. Should you have any doubts regarding the wall bearing capacity, consult
the suspension with a building specialist. The minimum diameter of the bolts for suspending
the heater is 12 mm. When mounting the anchor bolts follow the guide provided by the anchor
bolts' manufacturer.
Mount the anchors by the dimensional drawing (Figure 2, Figure 3) in 450 mm spacing. The heater verticality
after the release of the connecting screws can be aligned by means of slight turning. Double check the torque
of the suspension bolts on the heater and suspend the heater. Using the detent support in the bottom part
of the heater make sure it runs in parallel with the wall at the heaters OKHE 80-160 l!
o
C (setting to position „ECO" or „OPTIMUM") - Figure 12, Figure 13. For proper
Figure 4
- 9 -