CARLO GAVAZZI SMSA2P10 사용자 설명서 - 페이지 4
{카테고리_이름} CARLO GAVAZZI SMSA2P10에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. CARLO GAVAZZI SMSA2P10 16 페이지. Safety magnetic sensors, coded magnetic units

Fig. 1: Mechanical dimensions of the sensors and the operating units
parallelepiped housing.
Fig. 2: Dim. of std cylindrical SMS
(other available on request)
recommended to use brass or
nonmagnetic steel screws, so as
not to reduce the operating
distances of the sensors.
2.2
Cylindrical sensors
The SMS.. sensors (see the
mechanical dimensions in Fig. 2)
can be mounted using the M18x1
threaded part and the special nut,
24 spanner.
The CLS.. magnetic unit (see the
4
Fig. 3: CLS-A2 magnetic unit
dimensions
mechanical dimensions in Fig. 3)
can be mounted using the
countersunk hole, suitable for M4
screws. It is recommended to use
brass or nonmagnetic steel
screws, so as not to reduce the
operating distances of the
sensors.
3.
OPERATING MODES
An SMS.. sensor is "operated"
when all its safety and/or signaling