Alen MDF-70AE 소유자 매뉴얼 - 페이지 5

{카테고리_이름} Alen MDF-70AE에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alen MDF-70AE 12 페이지. Alen dehumidifier owner's manual

Alen MDF-70AE 소유자 매뉴얼

CONTROL PADS ON THE DEHUMIDIFIER

Power on
indicator light
Power
1 1

Control pads

1 1
POWER Pad
Press to turn the dehumidifier on and off.
2 2
Continue Pad
Select for the dehumidifier to operate
continuously for maximum dehumidification
until the bucket is full. The Humdity set
control pads cannot be used when
Continuous operation is on.
3 3
Humidity Set Control Pads
The humidity level can be set within a
range of 35%RH(Relative Humidity) to
80%RH(Relative Humidity) in 5%
increments.
For drier air, press the
to a lower percent value(%).
For damper air, press the
set a higher percent value(%).

Other features

Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
Auto Shut Off
The water level control switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position. When the setting humidity
is reached, the unit will be shut off automatically.
Continuous
Bucket full
operation on
indicator light
indicator light
5 5
Continuous
Full
C
Humidity%
2 2
3 3
pad and set
pad and
High fan
Normal fan
indicator
indicator light
light
Normal
Turbo
4 4
4 4
Fan speed Pads
Control the fan speed. Press to select either High or Normal
fan speed. Set the fan control to High for maximum moisture
removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Normal.
5 5
Display
Shows the set % humidity level while setting, then shows
the actual(+5% accuracy) room % humidity level.
Error Codes:
E1- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
E2- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P1- Unit is defrosting-- Allow the unit time to automatically
defrost. The error will clear after the unit self defrosts.
P2- Bucket is full-- Empty the bucket and replace in
the right position.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will
automatically re-start, in the settings last used, after the
power is restored.
4
Fig.1