Loss of power or turn-off during warm-up requires a
re-start from ambient.
4.
Change of state processes, i.e. solid to liquid or
liquid to gas, may introduce erroneous tuning parameters
during process warm-up.
GENERAL
1. Accurately measures, linearizes and displays temperature
in °F and °C.
2. Automatically calculates and displays parameters-heat
gain, and rate/reset time.
3. Can be field converted from relay output
state relay "T", to solid state driver "S" or to
a 4-20 MA output SCR driver "F".
4. Will remember its "entered" settings after power failure
or shut-off and not "Go To Sleep".
CAUTION: HIGH VOLTAGE AN0 HIGH TEMPERATURES CAN CAUSE INJURY
AN0 ARE A FIRE HAZARO. PLEASE REAO ALL INSTRUCTIONS, HAVE
ONLY SKILLED PROFESSIONALS WIRE THE UNIT, AND USE APPROVED
TEMPERATURE AND/OR PRESSURE SAFETY CONTROL. EVEN THE BEST
COMPONENTS CAN BE DAMAGED OR MAY NOT FAIL SAFE.
CONFIGURATION
Depending on the model number of the unit you have ordered,
vou will find one of four basic modules installed. The fifth
digit of the code indicate the output module type.
B - Relay 7A/5A @ 120/240 Vac
F - 4-20 mA (Proportional)
T - Triac 1 Amp @ 240 Vac
S - 20 VDC Pulsed for driving solid state relays
Example: 6050-F has proportional 4 to 20 mA heat
output.
Note: If you have not received your controller from the
factory direct, check to confirm that the correct module for
your application is installed. Since the modules plug-in,
and since controller plug into cases as well, previous users
may have changed modules, which can result in severe
controller damage.
"B", to solid