Electrolux Energy Star WT30H208DU 사용 설명서 - 페이지 8
{카테고리_이름} Electrolux Energy Star WT30H208DU에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux Energy Star WT30H208DU 18 페이지. Electrolux dishwasher instruction manual
Electrolux Energy Star WT30H208DU에 대해서도 마찬가지입니다: 사양 시트 (2 페이지)
WARNING
!
Before servicing unit switch off power at
the main circuit breaker and place a red
tag on the breaker to indicate work is
being done on that circuit.
Power supply 208 V 1ph or 240 V 1ph
Figure 8
Open the power supply terminal box and insert the jum-
pers provided as follows: two jumpers between terminals
1, 3, 5 and another two between terminals 2, 4 and 6.
Using a suitable power supply cable connect L1 and L2 to
terminals 5 and 6 respectively and the ground wire to the
terminal
.
Power supply 208 V 3ph or 240 V 3ph
L1
L2
L3
Figure 9
Open the power supply terminal box and insert the jum-
pers provided as follows: one jumper between terminals 1
and 2, one between terminals 3 and 4 and another
between terminals 5 and 6. Using a suitable power supply
cable, connect the three phases to terminals 1, 3, 5, and
the earth wire to the terminal
10
.
Connections provided for energy control
This appliance is designed for an external energy con-
sumption control.
11
12
Figure 10
Connect the energy peak controller across terminals 11
and 12.
CAUTION
!
A normally open (n.o.) contact of the
controller must be connected across ter-
minals 11 and 12. When this contact clo-
ses the boiler heating elements are
disconnected. Using the dishwasher in
these conditions may increase the cycle
time.
Safety devices
•
An automatic resettable thermally protectived device
incorporated in the windings of the electric pump cuts
off the electricity supply in the case of malfunctioning.
•
In the event of water mains failure, a back-flow
device prevents water in the boiler from returning into
the mains.
•
An overflow pipe, connected to the drainage outlet,
maintains the water in the tank at a constant level.
•
On models with a drain pump, a supplementary level
control device activates if the main level control
device is faulty.
Failure to comply with safety rules and regulations
relieves the manufacturer of all liability.
C3
WARNING MESSAGES DISPLAYED ON THE
CONTROL PANEL
NO WATER
A1
-
Check that the shutoff valve is open.
-
Check that the water inlet filter is clean.
-
Check the minimum main pressure is not less than
7.25 psi/50kPa.
-
Check that the overflow pipe is inserted (for applian-
ces without drain pump only).
INSUFFICIENT DRAINAGE
B1
-
Check if the overflow has been removed.