Athletica Sport Systems Moose 1.1 사용자 설명서 - 페이지 4
{카테고리_이름} Athletica Sport Systems Moose 1.1에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Athletica Sport Systems Moose 1.1 6 페이지. Ice puck freezer
Ice Puck Freezer
Product User Manual
Troubleshooting
n The unit is not turned on:
Check if the unit has been turned on.
Check the power supply - try a different power
source, for example, a different vehicle or power
outlet.
Ensure the plug and socket are connected properly.
Check if the fuse has been burned out or blown.
n Low refrigeration performance:
Ensure the unit isn't over-filled with items.
Ensure the items inside the unit aren't very warm
or hot.
Check if the lid is unlatched or open.
Check the integrity of seal on the lid, ensure it is
not damaged.
Make sure there is enough space around the unit
for proper ventilation (minimum of 100mm around
all sides).
Is the ambient temperature too high?
Is the temperature setting too high?
n Can hear running water inside the unit:
This is normal - due to the flow of refrigerant inside
the unit.
If unusual noise persists, ensure the unit is placed
on a level surface.
Error Protection Function
When the electronic control module of the
compressor malfunctions, the LED display will show:
ER1 / ER2 / ER3 / ER4 / ER5
and the compressor will stop working. If you are
able to identify the fault, remove it and then wait 3
minutes before starting the unit again.
NTC - display sensor failure detected.
ER0 / ER9 - after removing the fault, the internal
temperature will display within 2 seconds.
Code
Problem
Temperature sensor short
circuit. The compressor
ER0
enters a regular operating
mode, on for 30 min /
off for 30 min.
Input under-voltage
ER1
protection.
DC fan over-current
ER2
protection.
Compressor start-up
ER3
problem.
Rotation speed of
ER4
compressor is abnormal.
Temperature of control
ER5
module is abnormal.
Temperature sensor open
circuit. The compressor
ER9
enters a regular operating
mode, on for 30 min /
off for 30 min.
International Certification Approvals
Technical Data (DC)
Model
Climate Category
Protective Classification of
Electric Shock Resistance
Rated Volume DC (V)
DC Amps (A)
Watts
Rated Current for DC (A)
Refrigerant
Foam / Vesicant
554 Parkside Drive, Waterloo, Ontario, Canada N2L 5Z4 TEL 519-747-1856
720 Innovation Drive, Shakopee, Minnesota, USA 55379 TEL 763-249-7465
Solution
Change the temperature
sensor line.
1. Change the battery.
2. Lower battery
protection switch.
Change the fan.
Power off. Wait 30 mins.
Restart.
Change the main
controller.
Move the unit into a cool
place. Cool off the unit
and restart.
1. Tighten the
temperature sensor line.
2. Change the
temperature sensor line.
Moose 1.1
T / ST / N / SN
Class III
12 / 24V
15A
50W
4.2A / 2.1A
32g
C5H10/C-Pentane