Central core
6.1.4
First to the basket (see 5.1.11).
6.1.5
From the basket to the trays with the transportation tube. Routing
always from one side to the other side, see picture.
6.2
Fiber routing on the tray
6.2.1
Splicing
For heat shrinkable splice protectors:
•
slide the heat-shrinkable splice protector over one fiber.
•
fuse the fibers according to local recommendations and procedures.
•
after the fusion splice is made, install the heat shrinkable splice
protection (e.g. smouv) with appropriate heating source.
•
allow the splice protection to cool down to ambient temperature.
For ANT splice protectors:
•
fuse the fibers according to local recommendations and procedures.
•
after the fusion splice is made, install the ANT splice protector with
appropriate tool.
6.2.2
Storage
After each splice is made, the splice should be stored in the splice
holder. Do not deform the splice during insertion. The fiber slack should
be coiled into the tray. Follow the routing as shown.
6.2.3
If a tray for up to 16 heat shrinkable fusion splice protectors
is used
• The tray organizer has 6 locations to store splice protectors.
Each location can hold maximum 4 fusion splice protectors of type
smouv-1120-02 (length 45 mm, installed outer diameter is 2,4 mm)
or equivalent.
• After each splice is made, the splice should be stored as
indicated on the drawing. First protector in position 1, the second
in position 2. Continue for other fibers. Fiber nr 5 will be in position
1 of next location.
• If splice protectors are stored on the side with the 4 locations,
the fibers from the locations on the outside are first guided through
the passage between the locations and then coiled into the tray.