Aleo P23 설치 매뉴얼 - 페이지 6
{카테고리_이름} Aleo P23에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aleo P23 20 페이지.
Aleo P23에 대해서도 마찬가지입니다: 설치 매뉴얼 (20 페이지)
WARNING!
Contact with live parts due to unsuitable tools or weather condi-
tions: Risk of electric shock!
Only use approved, insulated tools for maintenance work on
live parts.
Work in dry conditions. Ensure that the electrical connections
of the solar module, the cables and the tools are dry.
_________________________________________________
RECOMMENDATION
Work in pairs so that in an emergency one person can help in the
case of injury. This is because the modules generate voltage as
soon as they are exposed to light. Therefore, parts of the system
are nearly always energised during the daytime.
6.2.2
Mechanical safety precautions
WARNING!
Glass can crack, break or splinter. Beware of injury!
Never step or sit on solar modules.
Avoid knocking and bumping the surface, the edges and cor-
ners of the glass panels.
WARNING!
Exposed live parts due to damaged glass: Risk of electric shock!
Only use modules with the insulation in perfect conditions.
CAUTION!
Sharp glass edges or flying glass splinters.: Beware of injury!
Always use suitable protective equipment (e.g. gloves and
safety goggles).
Be especially careful with the glass edges and corners of lami-
nates (frameless modules).
WARNING!
Damaged insulating back sheet. Risk of electric shock and burns!
Avoid any contact with the back of the module with sharp or
pointed objects.
Ensure that the back sheet remains undamaged.
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany |
7 Preparing for installation
7.1 Handling aleo modules
7.1.1
Store the aleo modules upright in the packaging units.
Do not stack the packaging units. This could damage the
Store the modules in dry conditions. Packaging is not wa-
Store the modules at an ambient temperature of max.
Store individual aleo modules in an upright position on
Avoid stacking individual modules, as well as the pallets
Store the modules in dry conditions.
Store the modules at an ambient temperature of max.
7.1.2
Using an underlay, incline the pallet (e.g. with a beam,
Use an underlay for inclining which supports the whole side
Remove the module from this side only. Remove the mod-
Observe the unpacking instructions on the module box.
Storing modules
Framed modules
Modules in packaging units:
-
WEIS
Make sure that each module has sufficient support.
modules.
terproof.
40 °C.
Individual modules:
-
wedges with suitable padding. Use adequate padding
between the modules.
they rest on.
40 °C.
Unpacking modules
Framed modules
NWEIS
height approx. 10 cm for 5° inclination), so that the opening
on the front of the box is elevated. The modules then lean
back in the box which makes it easier to remove them.
of the pallet (e.g. a beam). This keeps the modules support-
ed in the box along their entire width.
ule with the help of another person, if possible.
Installation manual Ver. 4.8, 05/2021, en
Page 6 of 20