pipes were often used for the earth ground, so it is im-
portant to make sure that your ground connection is
still valid and has not become loose or corroded. The
cold water pipe method may no longer be valid in some
locations due to requirements that the water meter be
isolated from the water mains with a length of PVC
pipe, thus interrupting the ground circuit. The safest,
and most reliable, approach may be to provide your
own ground. This can be accomplished by having a
licensed electrician drive at least five feet of copper-
jacketed steel grounding rod into the earth, and using
that for your grounding connection. If the hum persists
after all of the above suggestions have been tried, con-
tact the ATI customer service department for assis-
tance.