Anden AS35FP 빠른 시작 매뉴얼 - 페이지 2

{카테고리_이름} Anden AS35FP에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Anden AS35FP 4 페이지. Steam humidifier
Anden AS35FP에 대해서도 마찬가지입니다: 유지 관리 지침 (2 페이지)

Anden AS35FP 빠른 시작 매뉴얼
Water quality and canister selection
The Steam Humidifier operates on water with conductivity between 75 and 1,250 EC.
• Connect to water supply. Do not use RO or DI water.
• Use cold water only.
WATER QUALITY GUIDELINES
EC (1:1) Research
75-100
100-300
300-500
500-650
650-850
850-1250
above 1250
Capacity
Settings are chosen based on desired capacity.
STEAM CAPACITY
Amperage
Voltage
120V
11.5
208V
240V
120V
208V
16.0
(recommended)
(Nominal)
240V
(recommended)
Circuit board dip switches
For max capacity connect to 240V and set dip switch from 11.5 to 16 Amps.
2
Grains/Gal
Hardness
0-3
Naturally Soft
3-9
Naturally Soft
9-15
Slightly Hard
15-20
Moderately Hard
20-25
Hard
25-36
Very Hard
above 36
Extremely Hard
Softened
Maximum Steam Capacity (gal/day)
11.5
20.5
23.3
16.0
30.0
34.6
4
Recommended Canister by Voltage
120VAC
Installation Not Recommended
AS80LC
AS80LC
AS80LC
AS80LC
AS80LC
Installation Not Recommended
AS80
5
208VAC
240VAC
AS80LC
AS80LC
AS80LC
AS80LC
AS80
AS80
AS80
AS80
AS80
AS80
AS80
AS80
AS80
AS80
120
208
FACTORY SETTING FOR
11.5 AMP NOMINAL OPERATION
120
208
240
LED D8
RECOMMENDED SETTING
SLIDE DIP SWITCH #1 TO "ON" POSITION
FOR 16.0 AMP NOMINAL OPERATION
240
90-1959