Anden A65 설치 지침 매뉴얼 - 페이지 4

{카테고리_이름} Anden A65에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Anden A65 7 페이지. Humidifier control

Anden A65 설치 지침 매뉴얼
WIRING MODEL A65 WITH MODEL AS35 OR AS35FP STEAM HUMIDIFIER
The Model A65 control requires 24VAC� See FIGURE 6�
1. Disconnect power from the steam humidifier and HVAC system�
2. Connect 24VAC to the C and R terminals on the Model A65�
3. Connect the H terminals on the steam humidifier to the H terminals on the Model A65�
4. Snap the Model A65 front cover on the back plate� The 4-pin terminal aligns with the terminal
block receptacle on the back plate�
5. Proceed to SYSTEM CHECKOUT on page 8�
FIGURE 6 – RECOMMENDED WIRING FOR MODEL A65 CONTROL
AND MODEL AS35 STEAM HUMIDIFIER
STEAM HUMIDIFIER WITH MODEL A65
HUMIDIFIER CONTROL AND #4851
HUMIDIFIER CONTROL
BLOWER ACTIVATION RELAY
REMOVE WIRE
TYPICAL 24 VAC
"G" TO "G"
TERMINAL STRIP
IN FURNACE
THERMOSTAT
4851 RELAY
NOTE: 18 AWG WIRE
IS ACCEPTABLE FOR
24V INSTALLATIONS.
6
MODEL A65
C
24VAC
R
H
H
YELLOW
BLUE
P4
CIRCUIT BOARD
YELLOW
TRANSFORMER
WHITE/YELLOW
STEAM HUMIDIFIER
WHITE/BLUE
FIGURE 7 – RECOMMENDED WIRING FOR MODEL A65 CONTROL
AND MODEL AS35FP STEAM HUMIDIFIER
MODEL A65
HUMIDIFIER CONTROL
NOTE: 18 AWG WIRE IS ACCEPTABLE
FOR 24V INSTALLATIONS.
BLUE
90-2549
WHITE
C
24VAC
R
RED
H
H
24VAC
CIRCUIT BOARD
TRANSFORMER
STEAM HUMIDIFIER FAN PACK
YELLOW
BLUE
P4
YELLOW
BLUE
STEAM HUMIDIFIER
90-2550
7