(Advanced mode)
Interface of advanced mode
Press the value up and down
Advanced mode
button setting the value
Display
Neither
Display
Display
setting value
pressure unit
pressure unit
100ms
250ms
500ms
1000ms
Power-saving mode
Backlight off
Backlight on
Change backlight
Change backlight
Change backlight
Change backlight
color when
color when output1
color either output1
color when
output1 works
output2 works
and output2 work
or output2 works
Copy function:OFF
Copy function:ON
Copy function:ON
Slave device
Master device
Factory-fresh state
Factory-fresh
Factory-fresh
state:OFF
state:ON
Press the SET button to change menu
F -
DPS
Panel mount adapter + Front protective cover
Assembly type
EB:Panel mount
LB:Bracket
Assembly code
Step1-Front cover assembly

Copy /Key lock /Zero-clear Function

Copy Function
1.Hardware:Connect the second pin of master device with the third pin of slave
device,then power on after connecting.
2.Software:Set "CP-M" on master device. Set "CP-S" on slave device.
3.Icon of copy completed :
Repeat step 1 and 2 if copy failed.
4.Turn off the power,disconnected devices and restart it after setting.
Bottom row
value
Power supply: DC24(+) (Brown)
display
Power supply: DC24(-) (Blue)
Display
period
setting
Hysteresis
setting
Master device
Color choice in
basic mode
Backlight

Zero-Clear Funtion

setting
Press
and
simultaneously
to reset the display value to
zero.
Copy function
Press
and
Press
simultaneously.
button simultaneously.

Dimensions/Assembly Instructions

0
31
-0.5
Panel frame dimension
Unit:mm
Step2-Back cover assembly
Slave device
Output1(Black)
Output2(White)
Key lock Funtion
Lock:Press
and the SET button simultaneously.
Release it when the display turns to "LoCK on".
Unlock:Press
and the SET button simultaneously.
Release it when the display turns to "LoCK oFF".
Press any button will display "LCK" in lock on mode.
Press
and the SET
and the SET
button simultaneously.
Bracket
4-
3
29.6
t=1.6
20
14
Bracket dimension
Unit:mm
19
5.2

Output Mode Description

Basic mode: Set the pressure value P. When the applied pressure value is
greater than P + hysteresis value, the display will ON. When the applied
pressure value is less than P + hysteresis value, the display will OFF.
Mode setting-
Pressure setting-
Pressure
Set point value P
0
Output:ON
Output:OFF
Hysteresis mode:Set the pressure value H/L. When the applied pressure value is
greater than H, the display will ON. When the applied pressure is less than L,
the display will OFF.
Mode setting-
Pressure setting-
Pressure
Set point value H
Set point value L
0
Output:ON
Output:OFF
Window comparator mode:Set the pressure value H/L.When the applied pressure
value is greater than H + hysteresis value or less than L, the display will OFF.
When the applied pressure value is less than L + hysteresis value, the display
will ON.
Mode setting-
Pressure setting-
Pressure
Set point value H
Set point value L
0
Output:ON
Output:OFF
-High pressure(1000kPa) Unit:1kPa
Hysteresis value
-Low pressure(100kPa) Unit:0.1kPa
Hysteresis value-
Time
Time
Time
Time
Hysteresis value-
Time
Time