8. Connect the various input signals to the proper positions on the removable
terminal blocks. Be certain to check all connections and assure that inputs
and outputs are not intermixed. Refer to the next section for the various
connections.
9. The system should now be operational.
NOTE: 3820 Card Only:
Optical 1 = Video/Data
Optical 2 = Data
System Switch Settings
The data interface circuit used in this product has external switches that are used
to configure the various signal options. These are preset to RS-232 at the time of
shipment. If changes are required, the positions of these switches must be changed
in accordance with the following table.
Data Input/Output Plug-in
Switches 1,2,3,7,8,9 and 10 are used to select the desired protocol. Positions for
these are as follows:
Protocol
RS-232
RS-422/485 4-wire
point-to-point
RS-485 2-wire
auto xmit/receive
RS-485 4-wire
multidrop
RS-485 2-Wire
Zero xmit/receive
Switches 4, 5 and 6 are used only in the RS-485 configurations to select the
auto time interval that the unit will wait before switching back to the receive
mode (tri-state). Refer to the table on the following page for switch positions.
1
2
Off
Off
Off
Off
On
Off
Off
On
On
On
On
On
On
On
Off
5
3
7
8
Off
Off
Off
Off
On
On
Off
Off
On
On
9
10
Off
Off
On
On
On
Off
On
Off
On
Off