TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
10" ROUND DUCT
MOUNTING FRAME
(Built on Site)
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
7-1/2" x 11-1/4" TO
10" ROUND
TRANSITION
10" ROUND
DUCT
7-1/2" x 11-1/4" TO
10" ROUND
TRANSITION
Factory-shipped unit installed in existing construction.
7-1/2" x 11-1/4" TO
10" ROUND TRANSITION
CEILING
JOIST
(24" Centers
Shown)
10" ROUND
DUCT
MOUNTING
BRACKETS
10" ROUND
DUCT
MOUNTING FRAME
(Built On Site)
FINISHED CEILING
MATERIAL
VCDK040
I
TYPICAL INSTALLATION
WIRING
WHITE
TO
BLACK
WHITE
TO
BLACK
Use U.L. approved connectors to wire per local codes. Connect
ground wire to bottom of conduit box.
IMPORTANT:
Remove shipping tape from damper.
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCT CONNECTOR
(Intake)
DUCT CONNECTOR
(Discharge)
FACTORY SHIPPED
Horizontal discharge position.
(Factory Shipped)
2
MODELS
• VCDK050
I
• VCDK070
COVER PLATE
120 VAC
LINE IN
Housing Disassembled and
Rotated To Be Re-Assembled
To Position Shown
DUCT
CONNECTOR
CONNECTOR
(Discharge)
Vertical discharge
position.
I
DUCT
(Intake)