10.7.2 Module X61/ X81
Fig. 10 Mounting X61, X81 with clamps
Load level
clamping area
Clamping
0 mm - 293 mm
- long side -
120 mm - 293 mm
180 mm - 293 mm
180 mm - 220 mm
Clamping
0 mm - 200 mm
- short side -
Table mounting areas clamping for X61, X81
Load level
Load level
lay-in system
Load level II
- long side -
lay-in system
Load level I
- short side -
Table lay-in system for X61, X81
Page 14/20
- Modules can be mounted horizontally and vertically
- Please note the information on snow load (see Chapter 10.6.5)
Load level
Permissible
pressure (test load)
Load level I
2400 Pa
Load level II
3900 Pa
Load level III
5400 Pa
Load level IV
8000 Pa
Load level I
2400 Pa
Permissible
Permissible
pressure (test load)
suction (test load)
3900 Pa
2400 Pa
2400 Pa
2400 Pa
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
Permissible
suction (test load)
2400 Pa
2400 Pa
2400 Pa
5400 Pa
2400 Pa