Figure 2:FFO50 Flex Fire® Oxygen Fuel burner and burner block

6. Start-up

1.
Make sure gas hose and oxygen hose are properly connected to the burner.
2. Open the oxygen shut-off valve closest to burner, let the oxygen go through the burner with
30 Nm
3
/h as coolant to burner.
3. Open the gas flow control valve.
4. Adjust the oxygen flow to make sure oxygen/gas ratio is about 2.
5. The flow of oxygen and gas can be adjusted if needed.
Burner flame should be level and align with the centerline of combustion chamber.

7. Adjustment

1.
When the gas flow reaches the normal flow rate, the flame length could be adjusted by
flame length adjustment knob, shown in Figure 3.
2. Rotating the guide bolt (clockwise) to shorten the flame, shown in figure 3.
3. Rotating the guide bolt (counterclockwise) to extend the flame, is shown in figure 3.
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – FFO50 Operation Manual
Warning
3