If the supply of internal cooling air is stopped for more than 20 minutes, to prevent burner
being damaged, the burner should be removed and insert the ceramic fiber into the middle
of the seal plate. Lack of the supply of external cooling air for a long time will cause damage
to the seal plate.
To adjust the burner, the corresponding fixing bolts need to be loosened, and should be re-
locked after the adjustment is completed. Do not remove the gas metal hose or locking device
when the gas is not completely shut off.