NSL-F Series Operating Manual
The correlation between the table below and the software is as follows:
MPI-200 software: e.g. 4-mA set value display on PC
Node
Value name
Signal interface
X45a
Current loop signal
Note:
For further settings, please see also the description in the MPI-200 product information
Parameters/signal curve
mA or %
3
2
1
Parameter
4 mA Setpoint
20 mA set value
Underrange limit
Overrange limit
Warn-Sig: no Media
Warn-Sig: out of Spec.
Err-Sig: Overflow
Err-Sig: Underflow
Err-Sig: Global Failure
Mounting Orientation
Zero-Point (Offset)
Slope (Gain)
Damping
Sensitivity Optimization
Threshold Fine Tuning
Parameter name
4 mA setpoint
6
5
4
Source value
Linear signal
determined in the sensor
Node/module
Signal Int
Signal Int
Signal Int
Signal Int
Signal Int
Signal Int
Signal Int
Signal Int
Signal Int
Measure
Measure
Measure
Measure
Measure
Measure
1: Error signal: value underflow
2: Underdrive limit
3: 4 mA set value
4: 20 mA set value
5: Overdriven limit
6: Error signal: value overflow
Warning signal: no medium
Sensor is not submerged in the
medium
Signal can be adjusted between 2.40...22.00 mA