Error Codes
On Control Unit Display
If there is an error detected during the self test then it shows
this code for about 2 seconds before it switches itself OFF.
One or both cutters are not
electronically connected to
the unit.
Reasons: activated cutter,
damaged cable, plug not
completely connected.
Action: replace or reconnect
cutter. Switch ON procedure can
be repeated. If self test is OK CYPRES can be used again
Excessive pressure variations
during self test.
Possible reason: moving vehicle
or moving aircraft.
Action: Switch ON procedure can be repeated. If self test is OK
CYPRES can be used again
Low battery condition.
Action: contact Airtec / SSK
before further use
Power Down
Action: contact Airtec / SSK
before further use
Checksum Error
Action: contact Airtec / SSK
before further use
Pressure Sensor Error
Action: contact Airtec / SSK
before further use
If unit does not switch OFF after 14 h, or another code is shown on
display, or if there is no red light, do not use the CYPRES and contact
Airtec [email protected] or SSK [email protected] before further use