• Disconnect the cables from the programmer.
30- THERMOSTAT
o Remove top plate and control panel. Pull out the thermostat knob.
o Remove the rear panel and the thermostat bulp./cable socket from the switch
o Remove the two screws that attach thermostat/switch to the control panel
support. Take out the capillary of the thermostat from the harness.
30a- Temparature / Spin speed selection ROTARY SWITCH
o Remove top plate and control panel. Pull out the knob.
o Remove the cable socket from the switch
o Remove the two screws that attach switch to the control panel support.
31- PUSH BUTTONS
• Remove top lid, drawer and front panel.
• Remove the push button cover.
• Release the plastic snaps on the push button from the panel.
• Disconnect the cables.
32- PRESSURE SWITCH
• Remove top lid.
• Water level switch is turned 90º and removed from its bracket.
• Disconnect hoses and cable connections on the water level switch.
33- WATER INLET VALVE
• Remove top lid.
• Disconnect valve cables.
• Valve hose clamp is moved back on the hose.
• Remove the hose from the valve.
• Press the lock pin which secures the valve to the body, twist anti-clock
wise, and remove the valve.
.
Figure 12