TROUBlE ShOOTING
P R o B l e m
I n d I c a t o R
Red light in the
sensor flashes
continuously when
the user's hands
are within the
sensor's range.
Red light in the
No soap
sensor flashes
coming
(once) and the
out of
motor is operating.
the
spout
Red light in the
sensor does not
flash (once) when
user's hands
are within the
sensor's range.
Red light flashes
(once) and the
motor operates.
Soap
coming
out from
the spout
does not
stop
c a U s e
low battery.
soap has run low or
completely out.
the soap tank has
been filled but soap
has not reached the
spout.
the connectors
between the motor and
the power source are
not connected properly.
sensor is picking up
reflections from the
washbasin or another
object.
connectors between
the electronic unit and
the pump assembly
\ transformer are
disconnected or not
properly connected.
Batteries are
completely used up.
soap solidification at
the pipe.
the black connectors
between the pump
assembly and soap
dispenser are not
connected properly.
s o l U t I o n
Replace battery. see page 13
Refer to page 11 and refill the
soap tank.
Press the refill button located
at the bottom of the pump
until soap starts to come out
of the spout again.
connect the connectors
properly so that the white
o-ring is not visible. Refer to
page 9 to see how.
eliminate cause of reflection.
connect the electronic unit
connectors to the pump
assembly and transformer.
the batteries must be
replaced. see page 13
Fill the bottle with hot water
at 50/60c and run the pump
constantly.
connect the connectors
properly so that the white
o-ring is not visible. Refer to
page 9 to see how.