INSTALLATION AND OPERATION MANUAL
IP CAmERA-ENd
INSTALLATION (CLFE4US1TPC)
Off
Set the S1 10/100baseT dip switch to the appropriate rate based on the required maximum data rate and
maximum distance. oFF = 10baseT; oN = 100baseT
On
S1 S2 S3
Set the S2 Master/Slave dip switch to oN for "Master" mode.
For Extended UTP connection, set the S3 1- or 4-pair dip switch oN for 1-pair or oFF for 4-pair operation.
For Extended Coax connection, set the S3-1 switch oN.
For systems not utilizing PoE, connect the 12V Power Supply to the power connector of the CLFE4US1TPC. A power adapter
connector is provided to simplify connection.
Connect up to 4 IP cameras to the 10/100baseT Ethernet port(s) of the CLFE4US1TPC using standard Cat5/6 cables, each 100m
length (max).
The link LEd on the 10/100 connector should be "oN" to indicate proper connection between the camera and the CLFE4US1TPC.
Note: While each standard Ethernet port can operate at either 10 or 100 Mbps, the extended port is 100Mbps max. The recommended total
bandwidth limitation should not exceed 54Mbps and is above the upper limit for transmitting four cameras.
FIGURE 3 – POWER LEd INdICATORS
POWER
RED
Power is on
OFF
Power is off
FIGURE 5 – ETHERNET LEd INdICATORS
TRAFFIC
GREEN
Flashing – Connection is
oK with traffic
YELLOW
–
OFF
No connection
TECh SUPPORT: 1.888.678.9427
LINk
–
Connection is oK
No connection
FIGURE 4 – EXTENdEd LEd INdICATORS
TRAFFIC
GREEN
–
YELLOW
Flashing, Traffic present
ORANGE
–
OFF
No traffic
CLFE4US1TPC
10/100BaseT
Connection is oK,
10baseT mode
–
Connection is oK,
100baseT mode
–
INS_CLFE4US1TPC_REV–
10/11/11
PAGE 3