Comnet CLFE IPS Series 설치 및 운영 매뉴얼 - 페이지 11

{카테고리_이름} Comnet CLFE IPS Series에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Comnet CLFE IPS Series 19 페이지. High-power poe mid-span injector

Comnet CLFE IPS Series 설치 및 운영 매뉴얼
INSTALLATION AND OPERATION MANUAL
Classification
Choose the classification type for selected ports:
» "Bypass" for ignoring classification.
» ".3af" for IEEE 802.3af classification signature
Disconnect Type
Choose the disconnect type for selected ports:
» "None" for disabling disconnect. Once powered on the port will be ON forever.
» "AC" for AC disconnects.
» "DC" for DC disconnects.
Violation Type
Choose the violation type for selected ports during delivering state:
» "None" for bypassing violation checking.
» "Class Based" for limiting power based on the classification results. If classification is
» "User Defined" for limiting power based on user defined value.
Max Power
Choose the user defined power value. This value is used if the "Violation Type" is "User
Defined".
Power Inrush Control Choose the "Power Inrush Control" mode of selected port:
» "Normal" for IEEE 802.3af mode.
» "High Inrush" for Legacy devices which require more than 15.4W.For port to deliver more
» "Pre 802.3at" for devices supporting 802.3at. Use this mode for delivering more than
Select All
Check "Select All" to select all ports. Otherwise check each port number to select the
corresponding port
Commands
Apply:
Applies the user selected configuration on to the selected ports.
Tech SupporT: 1.888.678.9427
bypassed then "Class-0" will be used in Normal Mode and "ILIM/ICUT" values in High
power mode.
than 15.4W appropriate ILIM/ICUT value needs to be selected and classification needs to
be bypassed.
15.4W. Appropriate ILIM/ICUT value should be selected.
CLFE(X)IPS
INS_CLFE(X)IPS_REV–
12/15/11
PAGE 11