Comnet FDW1000M/C 설치 및 운영 매뉴얼 - 페이지 4
{카테고리_이름} Comnet FDW1000M/C에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Comnet FDW1000M/C 12 페이지. Optical wiegand, magstripe & f/2f data extender
INSTALLATION AND OPERATION MANUAL
FIGURE 6 – FDW1000/C TYPICAL CONNECTION
DC
Power
Supply
Access
Control
Panel
FIGURE 7 – FDW1000/R TYPICAL CONNECTION
DC
Power
Supply
Card
Reader
FIGURE 8 – OPTIC CONNECTIONS
TX
RX
TECH SUPPORT: 1.888.678.9427
1 8 – 16VDC
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
2 GND
RLY 4 N.O. 1
FDW1000 S
FDW1000 S
M
/C
RLY 4 COM 2
CENTRAL
CENTRAL
STATUS LED
RLY 4 N.C. 3
STATUS LED
STATUS LED
DATA
DATA
RLY 3 N.O. 4
EXTENDER
EXTENDER
1 EXP(+)
1 EXP(+)
RLY 3 COM 5
1 EXP(+)
2 EXP(–)
2 EXP(–)
RLY 3 N.C. 6
2 EXP(–)
GND 7
3 +5V OUT
3 +5V OUT
3 +5V OUT
AUX OUT 8
4 PROG RES 2
4 PROG RES 2
4 PROG RES 2
RLY 2 IN 9
5 PROG RES 1
5 PROG RES 1
5 PROG RES 1
RLY 1 IN 10
6 LED IN
6 LED IN
6 LED IN
7 D1/DOUT
7 D1/DOUT
7 D1/DOUT
8 D0/COUT
8 D0/COUT
8 D0/COUT
1 8 – 16VDC
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
2 GND
RLY 2 N.O. 1
FDW1000 S
M
/R
FDW1000 S
RLY 2 COM 2
REMOTE
REMOTE
RLY 2 N.C. 3
STATUS LED
STATUS LED
DATA
STATUS LED
DATA
RLY 1 N.O. 4
EXTENDER
EXTENDER
1 EXP(+)
1 EXP(+)
RLY 1 COM 5
1 EXP(+)
2 EXP(–)
2 EXP(–)
RLY 1 N.C. 6
2 EXP(–)
GND 7
3 +5V OUT
3 +5V OUT
3 +5V OUT
AUX IN 8
4 RLY 4 IN
4 RLY 4 IN
4 RLY 4 IN
5 RLY 3 IN
5 RLY 3 IN
5 RLY 3 IN
10
6 LED OUT
6 LED OUT
6 LED OUT
7 D1/DIN
7 D1/DIN
7 D1/DIN
8 D0/CIN
8 D0/CIN
8 D0/CIN
Bench Test and Set Up:
TX
RX
1.
Connect the Remote and Central unit Fiber Optic ports together using a
crossover connection as shown in the diagram.
2.
Connect a suitable power supply to both units.
3.
Apply power. After a short delay, both units' Status LEDs should flash with
a green pulse to indicate successful communication.
4.
Touch a jumper wire from the GND connection to the RLY 3 input on the
FDW1000/C. The relay should activate with an audible click. A VOM or
continuity tester should show RLY 1 N.O. Contacts on the FDW1000/R
closing when the RLY 1 input is connected to GND on the FDW1000/C.
5.
FDW1000 ships preset for Wiegand data format. Refer to Figure 5 on
Page 3 to set the Dip Switch to a different reader and panel format.
6.
Connect a reader to the FDW1000/R and a panel to the FDW1000/C.
Verify that card reads are being accepted by the access control system.
Perform any troubleshooting before installing the units in the field.
7.
If the EXP100 Expansion modules are used with this system, refer to
EXP100 integration information beginning on Page 8.
8.
When proper settings are verified, units are ready for final installation and
operation.
1 8 – 16VDC
RLY 4 N.O. 1
2 GND
M
/C
RLY 4 N.O. 1
FDW1000 S
M
/C
FDW1000 S
M
/C
RLY 4 COM 2
RLY 4 COM 2
CENTRAL
CENTRAL
RLY 4 N.C. 3
STATUS LED
RLY 4 N.C. 3
DATA
DATA
RLY 3 N.O. 4
RLY 3 N.O. 4
EXTENDER
EXTENDER
RLY 3 COM 5
1 EXP(+)
RLY 3 COM 5
RLY 3 N.C. 6
2 EXP(–)
RLY 3 N.C. 6
GND 7
GND 7
3 +5V OUT
AUX OUT 8
4 PROG RES 2
AUX OUT 8
RLY 2 IN 9
5 PROG RES 1
RLY 2 IN 9
RLY 1 IN 10
6 LED IN
RLY 1 IN 10
7 D1/DOUT
8 D0/COUT
1 8 – 16VDC
2 GND
RLY 2 N.O. 1
M
/R
RLY 2 N.O. 1
FDW1000 S
M
/R
FDW1000 S
M
/R
RLY 2 COM 2
RLY 2 COM 2
REMOTE
REMOTE
RLY 2 N.C. 3
STATUS LED
RLY 2 N.C. 3
DATA
DATA
RLY 1 N.O. 4
RLY 1 N.O. 4
EXTENDER
EXTENDER
1 EXP(+)
RLY 1 COM 5
RLY 1 COM 5
2 EXP(–)
RLY 1 N.C. 6
RLY 1 N.C. 6
GND 7
3 +5V OUT
GND 7
AUX IN 8
4 RLY 4 IN
AUX IN 8
9
9
5 RLY 3 IN
9
6 LED OUT
10
10
7 D1/DIN
8 D0/CIN
FDW1000(M,S)
R1 Input
Controls Strike
on Remote
RLY 4 N.O. 1
RLY 4 COM 2
RLY 4 N.C. 3
RLY 3 N.O. 4
RLY 3 COM 5
RLY 3 N.C. 6
GND 7
AUX OUT 8
RLY 2 IN 9
RLY 1 IN 10
RLY 2 N.O. 1
RLY 2 COM 2
RLY 2 N.C. 3
RLY 1 N.O. 4
RLY 1 COM 5
RLY 1 N.C. 6
GND 7
AUX IN 8
Door Strike
9
10
Output
INS_FDW1000_EXP100_REV– 04/25/12 PAGE 4