Electrolux EGG6242NOX 사용자 설명서 - 페이지 13
{카테고리_이름} Electrolux EGG6242NOX에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux EGG6242NOX 20 페이지. 60cm wide black gas hob with enamel pan supports.
Supply connections:
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.
The hob has a terminal block which is
marked as follows:
• L — Live terminal
• N — Neutral terminal
•
or E — Earth terminal
Before carrying out the connection, make
sure:
1.
The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2.
The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations
3.
The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
The appliance is supplied with a 3 core
flexible powercable with a 3 amp plug. If it
is necessary to change the fuse, use a 3
amp ASTA-approved (BS 1362) fuse.
A
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
The wires in the cord are coloured as fol-
lows:
Green and yellow
Blue
Brown
B
C
D
- Earth
- Neutral
- Live
Replacement of the connection cable
1.
Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2.
Connect the blue (neutral) wire to the
terminal which is marked with the let-
ter 'N' or coloured blue.
3.
Connect the brown (live) wire to the
terminal which is marked with the let-
ter 'L'. It must always be connected
to the network phase.
There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached to the outer sheath.
To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).
WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.
The replacement of electric cable
must be carried out exclusively by
the service force centre or by per-
sonnel with similar competencies,
in accordance with the current
regulations.
8.6 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
ENGLISH
13
A
B