Electrolux EGT6342YOK 사용자 설명서 - 페이지 12

{카테고리_이름} Electrolux EGT6342YOK에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux EGT6342YOK 20 페이지.

Electrolux EGT6342YOK 사용자 설명서
12
www.electrolux.com
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values. The
adjustable connection is fixed
to the comprehensive ramp
by means of a threaded nut
G 1/2". Screw the parts
without force, adjust the
connection in the necessary
direction and tighten
everything.
A) End of shaft with nut
B) Washer
C) Elbow (if needed)
Liquid gas
Use the rubber pipe holder for liquid gas.
Always engage the gasket. Then continue
with the gas connection.
The flexible pipe is prepared for apply
when:
• it can not get hot more than room
temperature, higher than 30°C;
• it is no longer than 1500 mm;
• it shows no throttles;
• it is not subject to traction or torsion;
• it does not get in touch with cutting
edges or corners;
• it can be easily examined in order to
make sure its condition.
The control of preservation of the flexible
pipe consists in checking that:
• it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
• the material is not hardened, but
shows its correct elasticity;
• the fastening clamps are not rusted;
• expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
A
B C
WARNING!
When installation is complete,
make sure that the seal of
each pipe fitting is correct.
Use a soapy solution, not a
flame!
8.3 Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Technical
Information" chapter).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.
8.4 Adjustment of minimum level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
• from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.