Trickle Speed Temperature Threshold
The temperature the fan will switch from Energy Recovery Mode to Trickle mode.
Usually this would be set to around 18-20°C to be slightly cooler than the
normal heating thermostat temperature. Default is 18°C.
Temperature Limit
This is the maximum temperature the fan will run until going into standby. The
higher the temperature the more heat will be extracted from the loft. Default
is 27°C. Note that this limit is ignored in radon mode.
Accessing Data Logger Menu
To access the menu of data that the unit stores press and hold the set button
for 5 seconds. The menu structure is shown below, press SET to move to the
next item:
5 second press
of Mode
Display: hEAt EnErGy - 00
Description: Total energy
consumption of the heater in
kWh
To exit the menu press SET for 5 seconds or wait for the screen to switch off.
Display: tot run – 0y – 00d
Description: total unit run
time in years and days
Display: Fan EnErGy - 00
Description: Total energy
consumption of the fan in
Display: trI run – 0y – 00d
Description: Total time
spent at trickle speed
Wh
12
Display: nor run – 0y – 00d
Description: Total time
spent at Energy Recovery
speed