AirTech 3AV155 수리 지침 - 페이지 3

{카테고리_이름} AirTech 3AV155에 대한 수리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. AirTech 3AV155 10 페이지.

AirTech 3AV155 수리 지침
Repair Instructions 3AV 30 - 430
General Remarks
Before disassembly the pump, isolate the electrical input and disconnect the operation liquid connec-
tion, and inlet and outlet connections. Disassemble and reassemble the pump on a level surface. Mark
all parts as they become accessible during disassembly to ensure correct positioning for reassembly.
Before starting disassembly, collect the parts, materials and standard tools, which are required for
disassembly and reassembly of the pump
Special Tools, Parts and Materials
Feeler gauge
Molykote G-n Paste or equivalent
Liquid sealant e.g. Epple 32
Metal straight edge
Loctite 242 and Primer
Solvent such as kerosene

Dismantling Pump

1
Remove five fixed pump casing screws (901)
Remove pump casing (101)
Remove inter casing (137)
Disassembling Inter Casing from Pump Casing
1.1
1.1.1
Type 3AV 95/3AV 130/3AV 155/3AV 330/3AV 430
Remove fixed hexagon socket countersunk head screw (901.2) at inter casing (137)
Remove inter casing (137) from pump casing (101)
1.1.2
Type 3AV 255
Remove fixed screwed plug (903) at pump casing (101)
Remove fixed hexagon socket head cap screw (914) at pump casing (101)
Turn around pump casing (101) and inter casing (137)
Remove inter casing (137)
.
3