4) Programming
With a pilot wire:
The appliance can be controlled remotely if its pilot wire is connected to an appliance fitted with a pro-
grammer, to a central programming unit or to an energy control system.
Chart indicating the orders the device can receive over its pilot wire
Orders received Current absent
Ref/neutral
oscilloscope
Mode achieved
Heating
temperature
With a separate programmer:
The appliance can also be programmed independently by inserting a programmer in the housing at the rear
of the control box.This programmer will create the ECO and COMFORT modes just as you have defined
them for your appliance.
This device enables holding, heating, and drying your towels.
It also enables heating your bathroom. For optimum heating, please do not obstruct
the air outlets located on the sides of the device.
1) Description of the control panel
2) Setting the CONFORT temperature
It is the temperature desired when the room is occupied.
a) Set the switch to
b) Set knob
, the indicator
c) Wait a few hours for the temperature to stabilise.
If the temperature setting does not suit you, adjust it using the adjusting screw
(to be measured between the pilot wire and the neutral).
CONFORT
CONFORT
setting
U
SING THE DEVICE
to the ON position, the
lights when the ambient temperature is below that desired.
Negative half-
Full alternance
alternance
230V
-115V
ECO
STANDBY
3°C to 4°C
Standby
below
temperature,
CONFORT
about 7°C
setting
Temperature setting knob
with Hors Gel position
and ability to restrict the
range.
Time adjustment knob TURBO 1/4h, 1/2h, 1h, 2h.
Power On indicator
TURBO indicator
TURBO control
ON/OFF switch
Heating indicator
indicator lights.
Positive half-
alternance
+115V
STOP LOAD
SHEDDING
Instant device
stop. Can also
be used for load
shedding.
.