Andrew 75E LFL Antenna 조립 지침 매뉴얼 - 페이지 9

{카테고리_이름} Andrew 75E LFL Antenna에 대한 조립 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Andrew 75E LFL Antenna 15 페이지. Rxtx antenna and co-located antenna systems
Andrew 75E LFL Antenna에 대해서도 마찬가지입니다: 조립 지침 매뉴얼 (13 페이지), 조립 지침 매뉴얼 (12 페이지)

ANTENNA ALIGNMENT

8
SKEW ALIGNMENT
Set the SKEW on AZ/EL Skew
Mount prior to placement of
Reflector on Mount Tube. Refer
to the skew value determined on page 2.
Loosen the (four) Skew Locking Bolts
until they are just finger tight and
rotate the AZ/EL Skew Mount to align
the Skew Indicator Mark with correct
number on skew scale, as shown.
o
Scale is in 2
increments.
Tighten Skew Locking Bolts to a torque
of 8 Ft-lbs (11 Nm).

MOUNT ASSEMBLY

9
Loosen (4) Azimuth Locking Bolts located on AZ/EL Mount and slide AZ/EL Mount over Mount Tube. Mount Tube
options may include the Tri-Mast Wall Mount, Ground Pole Mount, or Non-Pentetrating Roof Mount. Loosely
tighten (4) Azimuth Locking Bolts. Do not tighten securely untily Azimuth Alignment is determined and set.
AZIMUTH
LOCKING
BOLT
(4 PLACES)
MOUNT
TUBE
(OPTIONAL)

SKEW SETTING

SKEW
INDICATOR
MARK
SKEW
LOCKING
BOLTS
(4 PLACES)
AZ/EL MOUNT
Optional Non-Penetrating
Roof Mount
8
0
o
Optional Tri-Mast Wall Mount
Optional Ground Pole Mount